Curtiss Wright Embedded Systems Curtiss Wright
Contact Sales Contact Support Print Page

VXS-ENC-0011/12

4U 5 slot VXS/VME 19" rack mount chassis

  • VXS backplane options: 4 payload slots + 1 switch slot single star or 3 payload slots + 2 VME64x slots
  • Pluggable 500W Power Supply
  • 1x Cooling fan assembly
  • 4U high, 19" rack mount
  • Advanced EMC Shielding

The VXS-ENC-0011/12 rack mount chassis comes in a 4U height and supports a 5-slot VXS backplane. The VXS-ENC-0011 is equipped with a single star backplane with 4 VXS payload slots and 1 VXS switch slot. The VXS-ENC-0012 is equipped with a backplane with 3 VXS payload slots and 2 VME64x slots. The chassis complies to the IEEE 1101.10/.11 specifications with horizontal mounting for 6U x 160mm cards from the front and 6U x 80mm I/O cards from the rear to support Rear Transition Modules (RTMs).

The VXS-ENC-0011/12 has a 6U 500W power supply (occupies two reserved front card slots in chassis) and offers side to side airflow cooling. This chassis supports one or two additional power supplies; they can be integrated in the chassis by the factory or added by the customer. EMC compliance was addressed in the design of the VXS-ENC-0011/12 to enable it to meet the strict requirements of CE and FCC. Customers can use the VXS-ENC-0011/12 for their own system integration or we can integrate processing and recording boards into the VXS-ENC-0011/12 for a sub-system ready for application development.


Enclosure  
Physical  
   Width 17" (431.8mm)
   Height 7" (177.80mm)
   Depth 13.5" (344.29mm)
   Compliance IEEE 1101.10/.11 Card Cage
Configuration 5 front boards 6U x 160mm
5 rear transition boards 6U x 80mm
Cooling Side to side
3 x 8 CFM fans for RTM Area
4 x 52 CFM High Output fans for Front Board Area
Power Supplies 1 x 6U 500W Universal AC, occupies 2 6U card slots
Current Shared
5V @ 50A
3.3V @ 60A
12V @ 12A
-12V @ 4A
Power Inlet IEC-60320-C14 male power inlet
U.S. power cord included with chassis
Backplane Signal Layout 
VITA 41, VXS Switched Fabric backplane
VXS-ENC-0011: 4 VXS payload slots + 1 VXS switch slot single star
VXS-ENC-0012: 3 VXS and 2 VME64x Point-to-Point

 

Environmental
  Operating Storage/Transit
Temperature 0°C to +50°C -20°C to +70°C
Altitude
6,000 ft. (1,829m) 50,000 ft. (15,240m)
Humidity 5% to 95% Non-condensing 5% to 95% Non-Condensing
Shock 10 Gs @ 11ms 15 Gs @ 11ms (per ASTM 0775)
Vibration 1.0 Gs @ 10 to 330 Hz 1.2 Gs @ 5 to 330 Hz
Agencies Designed to meet UL 1950,
FCC, CE